DIS Data Dictionary - PDU DataCreated by JDBE at Ft. Huachuca,
Arizona
-
Current standard: IEEE 1278.1
Samples field
Size: 16
Data Type: unsigned
Description: This field shall specify the number of samples in this PDU. This field shall be represented by a 16-bit unsigned integer. If the Encoding Class is not encoded audio, this field shall be zero.
|